Immunohistochemistry and in situ hybridization results depend on precise dispensing, controlled slide temperatures and clean fluidics. Nexus Biomedical Services repairs and maintains automated IHC/ISH staining systems for hospital pathology departments and reference labs across New Jersey, Pennsylvania, New York, Texas and Delaware, so your advanced staining runs stay consistent and on schedule.
IHC/ISH systems we service
Automated immunohistochemistry and in situ hybridization staining platforms including Leica systems and other platforms with on-board antigen retrieval. Share the model and serial number and we will confirm support before booking a visit.
Common faults we fix
- Reagent dispensing errors, missed or uneven coverage
- Slide heater faults affecting antigen retrieval or hybridization temperatures
- Bulk fluid, pump, valve and waste line problems
- Evaporation or drying on slides during a run
- Barcode reader and slide or reagent identification errors
- Robotic arm, probe or drawer position faults
- Software, run log and LIS communication errors
Preventive maintenance
A planned visit typically covers cleaning and inspection of probes and dispensing paths, fluidics and waste checks, slide heater performance checks, filter replacement where specified, barcode reader checks, mechanical alignment and a full test run before handover. Most labs schedule preventive maintenance every 6 months because of the volume and value of the reagents involved.
Temperature verification and safety
After service we verify slide heater temperatures against a calibrated reference, confirm dispensing on a test run and record the results along with electrical safety testing in your service report.
What to send us
Manufacturer, model, serial number and asset ID; the protocol and slide positions affected; error codes; and whether the issue is mechanical or a staining-quality concern you have already reviewed with controls. Then request service or call (848) 405-6968.
Frequently asked questions
Is weak or patchy staining always an instrument fault?
No. Antibody, retrieval and tissue factors play a part. We check dispensing, heating and fluidics so your team can rule the instrument in or out.
How often should an IHC/ISH system be serviced?
Most labs schedule preventive maintenance every 6 months, following the manufacturer’s guidance.
Can you check slide heater temperatures?
Yes. Heater checks against a calibrated reference are part of every visit.
Do you coordinate with the manufacturer on reagent-rental systems?
Yes. We can coordinate with the OEM where a service agreement or warranty applies.